Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add filters








Year range
1.
Chinese Journal of Orthopaedics ; (12): 1283-1290, 2021.
Article in Chinese | WPRIM | ID: wpr-910717

ABSTRACT

Lumbar degenerative disease is one of the most common diseases in orthopaedic clinics, and the chronic low back pain caused by it seriously affects patients' living quality. Currently, intervertebral fusion and rigid fixation are the main surgical methods for lumbar degenerative disease. Although the intervertebral fusion and rigid fixation can achieve a higher fusion rate, due to the stress concentration of adjacent segments, the adjacent segment degeneration may occur and make the patient's satisfaction rate much lower than the imaging fusion rate. Dynamic fixation is a new fixing concept, which can control the abnormal motion of the spine segment while retaining part of the movement of the fixed segment. Moreover, dynamic fixation is also beneficial to reduce the degeneration of adjacent segments and the incidence of breakage of internal fixation. Nowadays, various lumbar transpedicular dynamic fixation systems have appeared on the market. Most of these transpedicular dynamic fixation systems are derived from the design of pedicle screws and rods used in spinal fusion surgery in the 1980 s and 1990 s. The original intention of their design is to stabilize the abnormal segments and reduce the pressure on degenerated intervertebral discs and facet joints, while maintaining the normal movement of relevant segments. By reviewing the biomechanical research, clinical efficacy, existing problems and advantages and disadvantages of common backward lumbar transpedicular dynamic fixation systems, this article intends to provide new ideas for the improvement of the backward lumbar transpedicular dynamic fixation system design, as well as offering surgical treatment strategies for clinicians.

2.
Practical Oncology Journal ; (6): 103-109, 2019.
Article in Chinese | WPRIM | ID: wpr-752822

ABSTRACT

Objective The aim of this study was to investigate the effect of TSP-1 gene on angiogenesis in human osteosar-coma and its mechanism of action. Methods MG-63 cells were transfected with constructing pBPLV-shRNA-TSP-1 vector and pBPLV-TSP-1 expression vector. Cell viability was measured by CCK8,and its invasive ability was measured by Transwell assay. The expression of CD36 in intracells was detected by immunofluorescence. The expression levels of TSP-1,CD36,p38MAPK,VEGF, VEGFR-1,EGF and PDGF were detected in MG-63 cells by qRT-PCR and Western blot. Results The cell viability and inva-sion ability were significantly increased after transfected pBPLV-TSP-1 vector compared with the empty vector group(P<0. 05), and significantly decreased after transfected pBPLV-shRNA-TSP-1 vector( P<0. 05). The expression of TSP-1,EGF,P38, PDGF,VEGF and VEGFR -1 at mRNA and protein levels was significantly increased after transfection pBPLV -TSP -1 ( P <0. 05),and significantly decreased after transfection pBPLV-shRNA-TSP-1 vector(P<0. 05). Conclusion TSP-1 gene can promote the proliferation and invasion of MG-63 cells,and promote the formation of human osteosarcoma,indicating its mechanism related to the increase of growth factors EGF,VEGF,PDGF and activation of P38-MAPK pathway.

3.
Chinese Journal of Microsurgery ; (6): 469-473, 2016.
Article in Chinese | WPRIM | ID: wpr-502552

ABSTRACT

Objective To verify BMP-2 and VEGF gene activated nanobone paste can effectively enhance the vertebral bone of ovariectomized goat.Methods From January,2011 to May,2016,the goats had been neutered by ovariectomy 6 months earlier to induceosteoporosis.Then surgery to established the model of vertebral bone defected with nanobone implanting,and the operation vertebrae divided randomly into 3 groups:control group,nanobone group and double gene activated nanobone group.Three months after operation the goats were sacrificed and removed the vertebrae.Micro CT analysis of micro three-dimensional structure of trabecular bone,scanning electron microscope (SEM) analysis of the two-dimensional structure of the vertebrae,the structure of trabecular bone was evaluated by movat pentachrome staining.Results The dual gene activated nanobone group compared with the nanobone group,the bone volume fraction (BV/TV) significantly increased (85% at 1.2 mm vs 43% at 1.2 mm,P < 0.05);the dual gene activated nanobone group compared with nanobone group,in the largest ROI (1.2 mm),TbTh increased 10.9% (374 ± 26.2 μm vs 337 ± 22.3 μm,P < 0.05);Trabecular distribution coefficient (TbPf) was significantly decreased (7.519 ± 0.184 mm-1 vs 7.529 ± 0.261 mm-1,P < 0.05);In the largest ROI (0.8 mm),trabecular distribution coefficient (TbPf) was significantly decreased (283 ± 36.4 μm vs 327 ± 31.2 μm,P < 0.05),In the largest ROI (0.8 mm),the trabecular bone volume (Tbn) was increased 20%(1.404 ± 0.283 mm-1 vs 1.173 ± 0.224 mm-1,P < 0.05);Cortical thickness over the implantation area showed asignificant increase of 43% in vertebrae(P < 0.05);The histological analysis revealed a more extensive osseointegration of the dual gene activated nanobone group,with the presence of anabundant osteoid tissue and an osteoblastic celllining.Conclusion BMP-2 and VEGF gene activated nano bone paste can effectively enhance the vertebral bone of ovariectomized goat.

4.
Chinese Journal of Tissue Engineering Research ; (53): 329-334, 2014.
Article in Chinese | WPRIM | ID: wpr-443769

ABSTRACT

BACKGROUND:The bone morphogenetic protein 2 (BMP2)/vascular endothelial growth factor (VEGF) dual gene activated nanobone putty has been constructed in the previous experiments. OBJECTIVE:To investigate the effects of osteogenesis and osteogenic gene expression in mice by implanting BMP2/VEGF dual gene activated nanobone putty. METHODS:Twenty-four Kunming mice (48 sides) were randomly divided into four groups. Animals in each group (12 samples) were injected different materials into the right thigh muscle pouches:nanobone putty+hBMP2/VEGF plasmid;nanobone putty+hBMP2 plasmid;blank plasmid+nanobone putty;nanobone putty only. The effects of osteogenesis were evaluated by radiography, histology and molecular biology analysis in 2, 4 weeks after operation. RESULTS AND CONCLUSION:Bone-like tissues were observed in groups of nanobone putty+hBMP2/VEGF plasmid and nanobone putty+hBMP2 plasmid after operation. There was apparent BMP2 and VEGF mRNA expression in group of nanobone putty+hBMP2/VEGF plasmid. Group of nanobone putty+hBMP2/VEGF plasmid was significantly better than group of nanobone putty+hBMP2 plasmid in the alkaline phosphatase levels, the speed of osteogenesisas and amount of new bone (P<0.05). Groups of blank plasmid+nanobone putty and nanobone putty had no obvious osteogenesis performance. Either BMP2/VEGF dual gene activated nanobone putty or BMP2 gene activated nanobone putty had the osteogenic ability in vivo. And the former was significantly enhanced in the speed and quality of osteogenesis.

5.
Chinese Journal of Trauma ; (12): 684-687, 2011.
Article in Chinese | WPRIM | ID: wpr-421469

ABSTRACT

ObjectiveTo explore the clinical outcome of one stage posteroanterior decompression and bone implant in the treatment of severe lower cervical spinal bony canal stenosis. Methods The study involved 29 patients with severe lower cervical spinal bony canal stenosis treated with one stage posteroanterior decompression and bone implant from April 2006 to March 2009. There were 11 patients with old fractures, seven with posterior longitudinal ligament ossification and 11 with cervical disc calcification. The course of disease ranged from 2 months to 3.2 years, average 1.4 years. The nerve function was rated as grade B in two patients, grade C in 19 and grade D in eight according to Frankel scale. The average Japanese Orthopaedic Association (JOA) score was 9.8. ResultsAll patients were followed up for 7-28 months (average 15.2 months), which showed bony fusion five months after operation, with fusion rate of 100%. The Frankel grade was increased for average 1.2 grades and the nervous symptoms alleviated remarkably. Mean postoperative JOA score was 13.8 and increased for mean 4.0, with mean amehoration rate of 55.6%. ConclusionsOne stage posteroanterior decompression and bone implant is a safe and effective method for treatment of lower cervical spinal bony canal stenosis, when the intraoperative electrophysiological monitoring can assure the operative safety.

6.
Chinese Journal of Tissue Engineering Research ; (53): 3023-3027, 2010.
Article in Chinese | WPRIM | ID: wpr-402461

ABSTRACT

BACKGROUND: For its extensive sources and specific biological characteristics, heterogeneous deproteinized bone (DPB) as the tissue-engineered scaffold material gets a good application prospect in repair of large segmental bone defects.OBJECTIVE: To prepare scaffold material by compositing modified heterogeneous DPB with recombinant human bone morphogenetic protein 2 (rhBMP2) and evaluate the osteogenic ability in repairing large segmental long bone defects in large-sized animals.METHODS: Twenty-four goats were randomly and evenly divided into three groups: DPB, autologous bone, and DPB+rhBMP2. Bone defects (20% in length) were made in the middle and lower segments of the right tibia of each goat, and according to group design,different bone grafts were implanted and fixed using semi-ring slot external fixer. At 4-24 weeks after surgery, X-ray examination was performed once every other 4 weeks. At 24 weeks after surgery, newly formed bones were taken out for determining the repair effects of bone defects through duat-energy X-ray analysis, histological observation, and biomechanical analysis.RESULTS AND CONCLUSION: The prepared DPB exhibited a three-dimensional porous structure, with a porosity of (78.5±6.45)% and pore size of (472.5±7.02) μm. Time-dependent bone repair was found in each group. Results regarding anti-compression test, three-point anti-bend test, and anti-torsion test were greatest in the autologous bone group, followed by the DPB+rhBMP2 group, and lastly the DPB group. There were no significant differences in tibial bone density, bone mineral content,anti-compression pressure and ultimate pressure, anti-bending load and ultimate toad, anti-torsion torque and ultimate torque between autologous bone group, DPB+rhBMP2 group and normal bone control group. These findings indicate that modified heterogeneous DPB composited with rhBMP2 has osteogenic ability equivalent to autologous bone in repairing large segmental long bone defects in goat tibias. Therefore, it can be applied as tissue-engineered scaffold material.

7.
Chinese Journal of Tissue Engineering Research ; (53): 7770-7774, 2010.
Article in Chinese | WPRIM | ID: wpr-402255

ABSTRACT

BACKGROUND:Studies have demonstrated that tetrandrine has protection on acute spinal cord injury,but the specific mechanism remains poorly understood.OBJECTIVE:To study the protection of tetrandrine on rat acute spinal cord injury and to study its mechanism from apoptosis pathway.METHODS:A total of 100 rats were randomly divided into 4 groups.All rats were prepared for spinal cord injury models using modified Allen method except that in the sham-surgery group.Methylprednisolone and tetrandrine was injected into rats in the methylprednisolone and tetrandrine groups by tail intravenous injection prior to and at 24,48 hours after model preparation.The same volume of physiological saline was injected in the sham-surgery and model groups.Basso-BeatUe-Bresnahan(BBB score)was recorded at 8 hours,1,3,7 and 14 days after model preparation.The morphological changes of spinal cord injury sites were observed by hematoxylin-eosin staining and the expressions of bcl-2 and bax were determined by immunohistochemistry.RESULTS AND CONCLUSION:The BBB score of methylpradnisolone and tetrandrine groups were significantly higher than that model group at 7 and 14 days(P<0.05),but there were no significant difference between the methylprednisolone group and tetrandrine group(P>0.05).Hematoxylin-eosin staining showed that the spinal cord injured severely at 3-7 days,the injury degree in the methylpradnisolone group and tetrandrine group was slighter than that of the model group,with smaller bax expression and greater bcl-2 expression(P<0.01).The findings demonstrated that,tetrandrine is able to protect neurons from apoptosis and promote the nerve function recovery by inhibiting the expression of Bax and promoting the expression of Bcl-2.Its effect is not inferior to methylprednisolone.

8.
Chinese Journal of Trauma ; (12): 420-423, 2010.
Article in Chinese | WPRIM | ID: wpr-389689

ABSTRACT

Objective To discuss the therapeutic options for treatment of subaxial cervical dislocation combined with facet locking. Methods There were 49 patients with cervical dislocations including 7 patients with dislocation at C3,4, 15 at C4,5, 14 at C5,6 and 13 at C6,7. Eleven patients were with old dislocation, with duration of dislocation ranging from 2 hours to 61 days. Neurologic status of the patients according to Frankel scale was graded A in 14 patients, grade B in nine, grade C in 10 and grade D in nine. All patients were treated surgically after closed reduction with skull traction. Results The successful reduction rate was 63% for fresh dislocation, with average improvement of 0.65 grade for spinal cord function. All bone grafts got fusion at four months after operation. Conclusion Therapeutic options are based on fresh or old dislocations, paraplegia or not, intervertebral disk injury severity, and reduction or not through traction for patients with lower cervical dislocations.

9.
Chinese Journal of Tissue Engineering Research ; (53): 3393-3397, 2008.
Article in Chinese | WPRIM | ID: wpr-407206

ABSTRACT

BACKGROUND:Half-ring sulcated external fixator is a bone external fixation device.Its structure is relatively simple,with multi-plane fixed,and small occupying space.So far,there are few experimental reports about construction of tibial defect model by it in large animals.OBJECTIVE:To validate the practicality and repeatability of half-ring sulcated external fixator in establishing tibial defect models in goats.DESIGN,TIME AND SETTING:The randomized controlled observation was performed at the Animal Laboratory of the Third Military Medical University from March 2005 to February 2007.MATERIALS:Nine healthy adult(Animal Center of Third Military Medical University);Half-ring sulcated external fixator,made by Professor Li of the Third Military Medical University;Osseous pin,ψ2.5 mm,Shanghai Medicai Instruments Co.,Ltd.METHODS:After animals were anesthetized,two needles were threaded in the same plane of cancellous bone about 1.5-2.0 cm above the superior articular surface of the tibia,named group 1.The angle between the two needles was 40°.One needle was threaded at the place of 3.0 to 5.0 cm under the group 1 and parallel with optional needle of the group 1,named group 2.Needles of group 4 were threaded at the cancellous bone that was 2.0 cm from the joint surface of inferior extremity of the tibia.One needle was threaded at the place of 3.0 to 5.0 cm from group 4 and parallel with optional needle of the group 4.The included angle between these two needles of group 2 and group 3 was 60°.There were totally 6 needles.Tibia was fixed by half-ring sulcated external fixator.According to the length of the tibia from X-ray,tibia and periosteum were amputated by wire saw between the two needles in the middle and inferior segment of the tibia to make segmental bone and periosteal defects of 20 percent of tibia.MAIN OUTCOME MEASURES:①Postoperative general state of the animals and effect of half-ring sulcated external fixator.②Self-repair of bone defects by X-ray and Lane-Sandhu scoring standards.RESULTS:Of the 9 selected goats,1 died of postoperative infection,and 1 developed pinhole infection and supplemented.All the others survived and were included in final analysis.The goats were awake within 2-6 hours after surgery and able to stand up to eat.The loosening nuts were screwed up.No external fixation failure or loosening was found.No skin was necrotic.Injured limb could touch the ground in 2 days,but could not bear load until 2 weeks.The goats could walk in three weeks with a slight limp,then moved freely without claudication in four weeks after the operation.At the 5th week after operation,the radiographs showed little periosteal reaction.At the 10th week after operation,sclerosis was found in the fracture ends,and medullary cavity started to close.Fifteen weeks after operation,the medullary cavity closed and periosteal reaction did not aggravate.Inaddition.Lane score was 0 at any time point.No bone formation was found in the histological examination at 5,10 and 15 weeks after operation,and Lane score was 0 at any time point.CONCLUSION:The goat model established in goat tibia with 20%defects by the half-ring sulcated external fixator shows no bone healing after 15 weeks by X-ray or histological exanimation,indicating this is a practical and repetitive method to establish animal models of large segmental defect for bone tissue engineering.

10.
Chinese Journal of Tissue Engineering Research ; (53): 4549-4553, 2008.
Article in Chinese | WPRIM | ID: wpr-407155

ABSTRACT

BACKGROUND: There are few reports about vascularization in the repairing of bone defect by heterogeneous deproteinized bone.OBJECTIVE: To verify the vascularization characteristics of heterogeneous deproteinized bone, tissue engineering scaffold material, in the repairing of large segmental bone defect.DESIGN, TIME AND SETTING: The randomized controlled animal experiment was performed between March 2005 and February 2007 at the Third Military Medical University, Chongqing, China.MATERIALS: Twenty-four 10 to 12 months old goats, weighing (22.5±2.5)kg, were obtained from the Animal Center of the Third Military Medical University, Chongqing, China. Segmental bone defects of 20 percent right tibia middle and inferior diaphysis of the 24 goats were made.METHODS: The 24 goats were divided into test group (n=16) and control group (n=8) randomly. Goats in test group were implanted with deproteinized bone+autologous MSCs+recombinant human bone morphogenetic protein-2 (rhBMP-2), goats in control group were implanted with autograft bone, and all fixed with half-ring sulcated external fixator. Every 4 weeks, 3 goats were killed after ink perfusing through femoral artery. A thick slice of new bone tissue was made to observe the vascularization.MAIN OUTCOME MEASURES: Vascularization of new bone observed through gross anatomy and imaging; vascular network of new bone observed through thick section, blood vessel amount and area measured by Image-proplus really image analysis software.RESULTS: No goat was infected or dead. Animal soft tissue was dyed black, blood vessels'size, ditribution and network structure were observed in subcutaneous tissue, fascia and periosteum. At 4 weeks postoperation implant margin became crude in the defect area; at 8 weeks postoperation transparent bone absorbing area of different size and irregular shape appeared; after 12 weeks postoperation high-dense calcification shadow appeared at the ends of defect bone and new bone connected with the ends completely. On 4 to 24 weeks postoperation, the blood vessel amount became large, alignment became regular, and their size and distribution became uniform. It showed no significant difference in blood vessel amount and area between 2 groups (P>0.05).CONCLUSION: Composite of heterogeneous deproteinized bone+autologous MSCs+rhBMP-2 has the same vascularization degree. of autogeneous bone graft in repairing of large segmental tibia defect.

11.
Chinese Journal of Nosocomiology ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-591179

ABSTRACT

OBJECTIVE To analyze the major reasons of wound infection after external fixator application and then introduce management measures to prevent following wound infections. METHODS Totally 542 patients adopting external fixators between May 2005 and May 2007 were retrospectively reviewed. All the external fixator-related infections were inspected and the excretions from these infected wounds were collected to perform bacterial culturing. RESULTS The total infection rate of these 542 patients after external fixator application was 2.77%. Among them, six were infected with the bacteria in distraction osteogenesis group and the infection rate was 8.82%; three were infected in bone un-union and bone defect group and the infection rate was 5.36%; whilest the common fracture-fixing group got the lowest infection rate of 0.39%. CONCLUSIONS Wire-crossing positions are the most frequently infected sites after external fixation and the drug-resisted bacteria are the most commonly detected pathogens. Thus, increasing the stability of fixators, enhancing the infection supervision of operation environment, draining the wound thoroughly and using antibiotics rationally are the most effective managing measures to prevent external fixator-related infections in orthopedics.

12.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-546576

ABSTRACT

[Objective]To evaluate therapeutics for lumbar tuberculosis. [Method]Data from 65 patients treated with five different therapeutics were retrospectively reviewed.Group A(n=14) was treated with focal debridement.Group B(n=15) with focal debridement and bone grafting fusion.Group C(n=9) with posterior focal debridement plus bone grafting fusion and internal fixation.Group D(n=12) with posterior fixation and anterior focal debridement plus,bone grafting fhsion.Group E(n=15) with anterior focal debridement plus bone grafting fusion and anterior internal fixation.Patients all received routine support and anti-tuberculosis therapy before and after operation.Follow-up, erythrocyte sedimentation rate was studied,and bone fusion and kyphosis correction with X-ray plain film and 3D-CT reconstruction were evaluated.[Result]There were not damages occurring in the great vessels,nerves or ureters.No recurrence was found during the follow-up of 12~16 months(average 13 months).Grafting bone were all fused after 4~6 months with an average time of 3.8 months.There was no missing of angel of kyphosis correction,complications of looseness or break of internal fixation.[Conclusion]Efficient anti-tuberculosis therapy and the debridement is the key for treatment of tuberculosis.The selection of fusion or internal fixation is depended on the severity of tuberculosis.Reasonable selection may improve the therapeutic effect of lumbar tuberculosis.

13.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-546143

ABSTRACT

[Objective]To find a simple and direct feasible method to detect bone tissue vascularize from comparing advantage or disadvantage of ink intravascular Dabble-VG dyeing and other tissue dyeing in the tissue section capillary vessel display.[Methods]One side femoral artery of 6 normal goat was mixed with liquor composed of 10 percentink,10 percent formaldehyde and 20 percent mannitol,volume ratio in 7∶2∶1.Stopped femoral vein effluent was black.To get off goat tibia,10 percent formaldehyde was fixed with.EDTA decalcification,cedar oil douse,fiat 50 to 100 micrometer pachy-section and compound ink-VG dyeing to observe capillary vessel.[Results]Compound ink-VG dyeing ould display relations of capillary vessel and surrounding tissue.But in control group,single HE,Masson and Weigert Resorcinol-aniline red dyeing after-stain VG dyeing ould display few capillary vessel and surrounding tissue,and recognize difficultly.[Conclusion]Compound ink-VG dyeing can display capillary vessel of bone clearly,and can disclose relationships of surrounding tissue as well.This method can try on in tissue vascularization detect.

14.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-544967

ABSTRACT

0.05).[Conclusion]Composite of heterogeneous deproteinized bone+autogeneous MSCs+rhBMP2 has the same ability of autogeneous bone graft to repair big experimental segmental tibia defect,thus it can be used as a scaffold in tissue engineering and for further study of immunogenicity and ossification ability.

SELECTION OF CITATIONS
SEARCH DETAIL